NSN 6150-01-483-5836 · NIIN 014835836 · FSC 6150
NO DASHES 6150014835836
In Stock
CABLE ASSEMBLY,POWER,ELECTRICAL
Miscellaneous Electric Power and Distribution Equipment
Application: NEXT ASSEMBLY P/N 9451502, USED ON: REENTRY SYSTEM TEST SET (RSTS)
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| AGAV | END ITEM IDENTIFICATION | NEXT ASSEMBLY P/N 9451502, USED ON: REENTRY SYSTEM TEST SET (RSTS) |
| AKRZ | TERMINATION TYPE | BOTH ENDS ALL CONDUCTORS CONNECTOR |
| AMQN | CONDUCTOR QUANTITY | 4 |
| BLNZ | STRAND QUANTITY PER CONDUCTOR | 56 |
| CXCW | CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | POWER CORD, W073-W075, W077-W085 |
| CXDC | ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 18 |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 |
| FEAT | SPECIAL FEATURES | C-13 CONNECTOR ONE END, C-14 SHROUDED PLUG OTHER END; UNIVERSAL POWER CORD |
| HUES | COLOR | SECOND POSITION JACKET CABLE BLACK |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLUE |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR BROWN |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR GREEN |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR YELLOW |
| MATT | MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| MATT | MATERIAL | FIRST POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC) |
| MATT | MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC) |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 9451693-01 | 24290 |
| 953 | 92194 |
| 9451693-01 | 98747 |
| 191631973 | FAQ15 |
| 953 | U5449 |