NSN 5915-01-255-8606 · NIIN 012558606 · FSC 5915
NO DASHES 5915012558606
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Application: MISSILE GUIDANCE AND TRACKING SET AN/SPG-55B
Technical characteristics
64 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.500 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.000 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 3.750 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 2.750 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| AGAV | END ITEM IDENTIFICATION | MISSILE GUIDANCE AND TRACKING SET AN/SPG-55B |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SIXTH FUNCTION 6TH RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIFTH FUNCTION 5TH RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FOURTH FUNCTION 4TH RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 60.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 0.033 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 0.033 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 0.033 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 0.033 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 0.033 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SIXTH FUNCTION 6TH RADIO INTERFERENCE 0.033 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.15 AND VOLTS DC 1ST RADIO INTERFERENCE 0.05 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.15 AND VOLTS DC 6TH RADIO INTERFERENCE 0.05 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.15 AND VOLTS DC 2ND RADIO INTERFERENCE 0.05 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.15 AND VOLTS DC 5TH RADIO INTERFERENCE 0.05 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.15 AND VOLTS DC 4TH RADIO INTERFERENCE 0.05 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.15 AND VOLTS DC 3RD RADIO INTERFERENCE 0.05 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 96906 |
| AHBP | INPUT TERMINAL IDENTIFICATION | MS3124E12-10P |
| AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 96906 |
| AHBT | OUTPUT TERMINAL IDENTIFICATION | MS3124E12-10S |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 25.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 2 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0 AND VOLTS DC 3RD RADIO INTERFERENCE 5.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 115.0 AND VOLTS DC 5TH RADIO INTERFERENCE 5.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 115.0 AND VOLTS DC 4TH RADIO INTERFERENCE 5.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 115.0 AND VOLTS DC 6TH RADIO INTERFERENCE 5.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0 AND VOLTS DC 2ND RADIO INTERFERENCE 5.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0 AND VOLTS DC 1ST RADIO INTERFERENCE 5.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.164 |
| CQRG | BODY MATERIAL | METAL |
| FEAT | SPECIAL FEATURES | EIGHT FILTERED AND TWO UNFILTERED FUNCTIONS |
| STYL | STYLE DESIGNATOR |