LAMP,INCANDESCENT
Electric Lamps
Application: TICONDEROGA CLASS CG (47); KIDD CLASS DDG; WASP CLASS LHD; VIRGINIA CLASS CGN (41); SPRUANCE CLASS DD (963); FMS- KNOX CLASS FF; FORRESTAL CLASS CV; NIMITZ CLASS CVN; TARAWA CLASS LHA; FMS- NEWPORT CLASS LST
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AFST | LIGHT OUTPUT RATING | SINGLE RATING SPHERICAL CANDLEPOWER NOMINAL 0.300 |
| CSMC | BULB LIGHT TRANSMISSION CHARACTERISTIC | TRANSPARENT |
| CTQM | CURRENT RATING FOR WHICH DESIGNED | AMPERES NOMINAL 0.080 |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 0.520 |
| AFSC | WIRE LEAD LENGTH | INCHES MINIMUM 1.000 |
| ZZZK | SPECIFICATION/STANDARD DATA | MANUFACTURERS STANDARD 08108-2128 |
| AFSX | FILAMENT HEAVY DUTY SERVICE RATING | NOT RATED |
| AGAV | END ITEM IDENTIFICATION | TICONDEROGA CLASS CG (47); KIDD CLASS DDG; WASP CLASS LHD; VIRGINIA CLASS CGN (41); SPRUANCE CLASS DD (963); FMS- KNOX CLASS FF; FORRESTAL CLASS CV; NIMITZ CLASS CVN; TARAWA CLASS LHA; FMS- NEWPORT CLASS LST |
| AGDV | EMITTED LIGHT CHARACTERISTIC | COLORLESS |
| AMSE | VOLTAGE RATING | VOLTS NOMINAL 14.000 |
| AFSP | FILAMENT DESIGNATION | C-2F |
| CRPS | BASE STYLE | |
| CWBF | RATED AVERAGE LIFE | HOURS |
| BDWW | WATTAGE RATING | WATTS 1.120 |
| CRSK | BULB STYLE | |
| CSJW | BULB DESIGNATOR | T-1 3/4 |
| AFSV | AVERAGE LIFE RATING IN HOURS | 50000.0 |
Cross-references
47 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 92184 | 19790 |
| 175-2182 | 34165 |
| 531157-011 | 3B150 |
| 00041-007 | 50037 |
| B4 | 51054 |
| 531157-011 | 49956 |
| 2182 | 50035 |
| S21010-06 | 50012 |
| 136-0023 | 54001 |
| 2182 | 55335 |
| G 1631 | 55292 |
| 531157-011 | 54X10 |
| 1706-4809 | 60114 |
| PL2182 | 58451 |
| S-1527 | 58815 |
| 92184 | 58634 |
| LTX2182 | 61342 |
| 2182D | 62607 |
| CM2182 | 71744 |
| 2182 | 71744 |
| 835238 | 77948 |
| LA428 | 76854 |
| 428 | 76854 |
| 108 | 76854 |
| 39013-2182 | 83961 |
| 5040-1464 | 91802 |
| 3590A20 | 91802 |
| 2182 | 92966 |
| 3452410-3 | 95301 |
| 2182 | 94988 |
| 2182 | 95146 |
| OL-2182 | J5705 |
| L.1533 | K0316 |
| OL-2182 | S3774 |
| 741WE | K3197 |
| L.1533 | K0690 |
| 2182 | 00303 |
| PKS-192-18 | 03034 |
| PKS-192-13 | 03034 |
| 2182 AS25 | 05464 |
| 2182 | 05464 |
| 2182 | 08108 |
| 7106 | 08108 |
| 2182D | 08806 |
| 2182 | 07294 |
| 2182 | 13050 |
| 1209637-00 | 15476 |
Supersedes
This item replaces cancelled NIINs 001792298 · 002555635 · 004053800 · 007893376 · 008537802 · 009447021 · 010417341. An older drawing citing one of those numbers resolves here.