NSN 6665-01-585-2354 · NIIN 015852354 · FSC 6665
NO DASHES 6665015852354
In Stock
RADIACMETER
Hazard-Detecting Instruments and Apparatus
Technical characteristics
8 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 8.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 9.200 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.500 |
| AMRM | RADIATION TYPE AND FUNCTION | BETA RAYS MEASURES AND GAMMA RAYS MEASURES |
| APPJ | RADIATION RANGE PER HOUR | MILLIROENTGENS 0.2 TO 50000.0 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | DC 3.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | ION CHAMBER MODEL 9-3 LUDLUM |
| FEAT | SPECIAL FEATURES | RUGGED AIR IONIZATION CHAMBER; PERFORMS BETA-GAMMA DOSE RATE MEASUREMENTS OVER A FIVE-DECADE SPAN RANGING FROM BACKGROUND TO 500 MSV/HR (50 R/HR); CHAMBER VOLUME: 13.4 CU IN; WINDOW: 7 MG/CM2 ALUMINIZED MYLAR; WINDOW AREA: 6.2 IN2; BETA SHIELD: RETRACTABLE 1000 MG/CM2 PHENOLIC SLIDE; SIDE WALL: 1000 MG/CM2 ALUMINUM AND ACRYLIC; SIX-POSITION SWITCH SELECTS OFF, X10K, X1K, X100, X10, AND X1; EACH RANGE HAS FRONT-PANEL MOUNTED CALIBRATION CONTROL; ALSO INCLUDES AUDIO OUTPUT, RESET, AND ZERO ADJUST CAPABILITIES; ALSO HAS EANS TO ZERO THE ELECTROMETER LEAKAGE CURRENT; APPROX. WT: 3.6 LBS |