| MRC | Requirement | Value |
|---|---|---|
| STYL | STYLE DESIGNATOR | |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 1 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 10.741 AND MEGAHERTZ BLANK 10.7466 AND MEGAHERTZ BLANK 10.7474 AND MEGAHERTZ BLANK 10.753 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.112 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.188 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -40.0 TO 80.0 |
| AFSV | AVERAGE LIFE RATING IN HOURS | 10000.0 |
| AKNA | INCLOSURE TYPE | ENCASED |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 60.0 AND MAXIMUM BLANK 5.0 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 5.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 1 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 600.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED CRYSTAL BLANK |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.760 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 10.747 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 2 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.960 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.510 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.760 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 600.0 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 10.7466 AND MEGAHERTZ BLANK 10.7474 |