NSN 6680-01-364-0267 · NIIN 013640267 · FSC 6680
NO DASHES 6680013640267
In Stock
TRANSMITTER,LIQUID QUANTITY
Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments
Application: DAMAGE CONTROL ALARM MONITORING SYS
Technical characteristics
6 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACDC | CURRENT TYPE | DC |
| ACZB | FREQUENCY RATING | KILOHERTZ MINIMUM 0.0 AND KILOHERTZ MAXIMUM 10.0 |
| AGAV | END ITEM IDENTIFICATION | DAMAGE CONTROL ALARM MONITORING SYS |
| AMSE | VOLTAGE RATING | VOLTS MINIMUM 7.0 AND VOLTS MAXIMUM 28.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | LOOP POWERED 4-20MA TRANSMITTER |
| FEAT | SPECIAL FEATURES | TEMPERATURE: TEMPERATURE, OPERATING MINUS 40 TO 85 DEG C; MOUNTS DIRECTLY ON FLOWMETER |