NSN 5915-00-237-6175 · NIIN 002376175 · FSC 5915
NO DASHES 5915002376175
In Stock
FILTER,LOW PASS
Filters and Networks
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 775.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.4 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.136 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.046 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -54.0 TO 110.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.000 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.500 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.000 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 450.00 AND GIGAHERTZ BLANK 1.10 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MAXIMUM BLANK 1.0 AND MINIMUM BLANK 40.0 |
| CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 450.0 AND GIGAHERTZ BLANK 1.1 |
| CTJS | UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 2.000 |
| STYL | STYLE DESIGNATOR | |
| CQRG | BODY MATERIAL | METAL |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 450.00 AND GIGAHERTZ BLANK 1.10 AND GIGAHERTZ BLANK 2.00 AND GIGAHERTZ BLANK 4.10 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, PLUG OUTPUT 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 2 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 3.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, PLUG INPUT 1 |