NSN 6115-00-081-2034 · NIIN 000812034 · FSC 6115
NO DASHES 6115000812034
In Stock
GENERATOR SET,DIESEL ENGINE
Generators and Generator Sets, Electrical
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AZBP | PRIME MOVER IDENTIFYING NUMBER | MODEL NO. NHC-4 |
| AMSB | IDENTIFYING NUMBER | PART NO. 55J440421Y5 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 AND HERTZ NOMINAL 50.0 |
| AYHD | POWER FACTOR IN PERCENT | 80.0 |
| AYHE | EXCITOR TYPE | SEPARATELY EXCITED |
| AYQZ | PRIME MOVER STARTING METHOD | ELECTRIC MOTOR |
| AYSA | CRANKING VOLTAGE IN VOLTS | 24.0 |
| AZBN | PRIME MOVER MANUFACTURER NAME | CUMMINS ENGINE CO. |
| AAXX | MOUNTING TYPE | SKID |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 102.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 60.000 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 36.000 |
| ACDC | CURRENT TYPE | AC |
| AYHB | LINE TO LINE VOLTAGE IN VOLTS | 416.0 AND 208.0 AND 240.0 AND 380.0 AND 90.0 AND 220.0 |
| AZCB | HOUSING TYPE | INCLOSED |
| AZCL | AMBIENT TEMP IN DEG CELSIUS | 25.0 |
| AZCM | TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 60.0 |
| BFMF | COOLING METHOD | RADIATOR |
| AYGY | AC WATTAGE RATING | KILOWATTS 60.0 AND KILOWATTS 45.0 |
| FAAZ | PHASE | THREE AND SINGLE |
| AYHC | LINE TO NEUTRAL VOLTAGE IN VOLTS | 240.0 AND 120.0 AND 220.0 AND 110.0 |