23 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.375
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500
ABTBMOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.260
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 420.0
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
ADAQBODY LENGTHINCHES MAXIMUM 5.312
ADATBODY WIDTHINCHES MAXIMUM 4.437
ADAUBODY HEIGHTINCHES MAXIMUM 4.850
AEHZMAXIMUM OPERATING TEMPCELSIUS 80.0
AGAVEND ITEM IDENTIFICATIONHAUGE CLASS T-AK 3000; AIRBORN MOBILE DIR AIR SPT CTL (2ID),(02M JUL83)(AN/UYQ-3A); ARLEIGH BURKE CLASS DDG; TACTICAL AIR OPNS MODULE (AN/TYQ-(23); RADIO SET, AN/GRC-171A; MARINE AIR TRAFFIC CONTROL LANDING SYSTEMS
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 2 AND SECONDARY 4
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 2.7
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 5.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.0
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 120.00
FEATSPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
TTQYTERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 18