Home / MS parts / NSN 5925-00-549-6803
NSN 5925-00-549-6803  ·  NIIN 005496803  ·  FSC 5925
NO DASHES 5925005496803
In Stock

CIRCUIT BREAKER

Circuit Breakers

Application: SOF C-130 SERIES AIRCRAFT

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 3.719
ADATBODY WIDTHINCHES NOMINAL 0.990
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.063
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.750
AFJNFRAGILITY FACTORMODERATELY RUGGED
AGAVEND ITEM IDENTIFICATIONSOF C-130 SERIES AIRCRAFT
AJECBOSS HEIGHTINCHES NOMINAL 0.156
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 70.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 28.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 2
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 3.239
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 40.000
PRPYPROPRIETARY CHARACTERISTICSPACS
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
FEATSPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
MATTMATERIALCASE PLASTIC
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 4000.0

Supersedes

This item replaces cancelled NIIN 008125965. An older drawing citing one of those numbers resolves here.