NSN 4140-00-814-5758 · NIIN 008145758 · FSC 4140
NO DASHES 4140008145758
In Stock
FAN,VANEAXIAL
Fans, Air Circulators, and Blower Equipment
Application: C-130B/E
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ZZZV | FSC APPLICATION DATA | VENT SYSTEM COMPONENTS,ACFT |
| SFTT | SURFACE TREATMENT | HOUSING INSIDE ANODIZE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FLANGE 2 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| SFTT | SURFACE TREATMENT | BLADE LACQUER ALUMINUM |
| STYL | STYLE DESIGNATOR | |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| AKNA | INCLOSURE TYPE | OPEN |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 1700.000 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 OR AC 200.0 |
| AGAV | END ITEM IDENTIFICATION | C-130B/E |
| AGBD | ELECTRICAL CONNECTION TYPE | TERMINAL |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 4.0 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| AAYD | STAGE QUANTITY | 1 |
| ADNK | FLOW DIRECTION | INWARD |
| SFTT | SURFACE TREATMENT | HOUSING OUTSIDE ANODIZE |
| NMBR | QUANTITY | 1 |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 1.500 |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 9.015 |
| MATT | MATERIAL | BLADE ALUMINUM |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| CBBL | FEATURES PROVIDED | NONSPARKING AND SAFETY IMPELLER GUARD |
| FAAZ | PHASE | THREE |
| AKCV | DRIVE TYPE | DIRECT |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| MATT | MATERIAL | HOUSING ALUMINUM |
Supersedes
This item replaces cancelled NIIN 014755719. An older drawing citing one of those numbers resolves here.