NSN 6680-00-886-3605 · NIIN 008863605 · FSC 6680
NO DASHES 6680008863605
In Stock
TRANSMITTER,RATE OF FLOW
Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments
Application: HC-130H A/H ACFT
Technical characteristics
13 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| AARA | TERMINAL QUANTITY | 1 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 8.000 |
| ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
| ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | PART NO. CA3102-165-1P-F1 |
| AXGY | MOUNTING METHOD | FLANGE |
| BGNL | MEASUREMENT RANGE | GALLONS PER MINUTE 0.0 TO 600.0 |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 400.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.500 |
| FEAT | SPECIAL FEATURES | PROOF PRESSURE 240 PSI;OPERATING TEMPERATURE -65 DEG F TO 160 DEG F;LENGTH BETWEEN FLANGES 8.000 INCHES;TRANSMITTER OUTPUT TO METER 28 VDC;WEIGHT 4.6 LBS;FREQUENCY AT 600 GPM 19.995 HZ CYCLES PER SECOND;RPM 1200 MAXIMUM;RATED LIFE 500 HR AT 400 GPM;T.O. 5L14-7-4-3 |
| AMSE | VOLTAGE RATING | VOLTS NOMINAL 115.0 |
| AGAV | END ITEM IDENTIFICATION | HC-130H A/H ACFT |
| ACDC | CURRENT TYPE | AC |
Supersedes
This item replaces cancelled NIIN 011315296. An older drawing citing one of those numbers resolves here.