NSN 5950-01-027-9545 · NIIN 010279545 · FSC 5950
NO DASHES 5950010279545
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.116 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.188 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.875 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.250 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.077 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC NOMINAL 139.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 43.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 5 |