CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

45 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.925 AND INCHES MAXIMUM 1.955
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
AJECBOSS HEIGHTINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.155
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.583 AND INCHES MAXIMUM 2.763
AKPXPOLE QUANTITY2
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MINIMUM 2.485 AND INCHES MAXIMUM 2.515
ADATBODY WIDTHINCHES MINIMUM 1.485 AND INCHES MAXIMUM 1.515
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 5.0 AND DC 1.0
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 115.0 AND DC 50.0
CPRWACTUATOR FUNCTIONTRIP-RESET
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
AFJNFRAGILITY FACTORMODERATELY RUGGED
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 3.000 AND MAXIMUM AT 200 PCT 10.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF
CRTKSWITCH TERMINAL TYPETAB, SOLDER LUG
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.0 AND AMPERES DC 2.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0 AND DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0 AND DC 2000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
FREQFREQUENCY IN HERTZ60.0
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
MATTMATERIALCASE PLASTIC
TESTTEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 05869-711570
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 4
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.547
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.047 AND INCHES MAXIMUM 2.077