NSN 5930-01-123-9509 · NIIN 011239509 · FSC 5930
NO DASHES 5930011239509
In Stock
SWITCH,THERMOSTATIC
Switches
Application: HULL OBRP
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AASA | THREAD LENGTH | SINGLE THREADED BUSHING INCHES NOMINAL 0.710 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.380 |
| ABPM | BODY DIAMETER | INCHES MINIMUM 0.635 AND INCHES MAXIMUM 0.665 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.000 |
| AGAV | END ITEM IDENTIFICATION | HULL OBRP |
| AKBY | TEMP SENSING ELEMENT TYPE | IMMERSION WELL |
| ASDB | WIDTH ACROSS FLATS | INCHES NOMINAL 1.000 |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 14 |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | SINGLE THREADED BUSHING INCHES 0.500 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | WIRE LEAD |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 2.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT NOMINAL DEGREES FAHRENHEIT 145.00 AND DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT 140.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE DC AT SEA LEVEL 28.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 115.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| STYL | STYLE DESIGNATOR | |
| THSD | THREAD SERIES DESIGNATOR | SINGLE THREADED BUSHING NPT |