Home / MS parts / Electrical & Electronic Components / NSN 5950-00-933-0430
NSN 5950-00-933-0430  ·  NIIN 009330430  ·  FSC 5950
NO DASHES 5950009330430
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

21 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC MAXIMUM 700.0
ADAUBODY HEIGHTINCHES NOMINAL 4.155
ADAQBODY LENGTHINCHES NOMINAL 3.000
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.859
CMLPTHREAD QUANTITY PER INCH32
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
ADATBODY WIDTHINCHES NOMINAL 2.560
AARGRELIABILITY INDICATORNOT ESTABLISHED
AKNAINCLOSURE TYPEHERMETICALLY SEALED
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 110.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 120.00
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 200.0
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.297
TTQYTERMINAL TYPE AND QUANTITYPIN 23
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP THREADED HOLE(S)
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC MAXIMUM 60.0
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE