NSN 6145-01-280-6133 · NIIN 012806133 · FSC 6145
NO DASHES 6145012806133
In Stock
CABLE,SPECIAL PURPOSE,ELECTRICAL
Wire and Cable, Electrical
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| ABJH | TEMP RATING | CELSIUS 200.0 |
| ADVL | CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.075 |
| AMQN | CONDUCTOR QUANTITY | 1 |
| BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 |
| CXCW | CONDUCTOR FORM | SINGLE CONDUCTOR STRANDED |
| CXDC | ROUND CONDUCTOR SIZE | SINGLE CONDUCTOR AWG 26 |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 38 |
| CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 1 |
| CXFK | VOLTAGE RATING | SINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0 |
| FEAT | SPECIAL FEATURES | PRIMARY INSULATION AND OUTER JACKET ARE SODIUM AND AMMONIA ETCHED |
| HUES | COLOR | FIRST POSITION COVER SINGLE CONDUCTOR GREEN |
| HUES | COLOR | FIRST POSITION JACKET CABLE WHITE |
| MATT | MATERIAL | THIRD POSITION COATING SINGLE CONDUCTOR SILVER |
| MATT | MATERIAL | CORE CONDUCTOR SINGLE CONDUCTOR COPPER |
| MATT | MATERIAL | FOURTH POSITION JACKET SINGLE CONDUCTOR PLASTIC POLYTETRAFLUOROETHYLENE |
| MATT | MATERIAL | FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC POLYTETRAFLUOROETHYLENE |
| MATT | MATERIAL | SECOND POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR COPPER |
| MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR SINGLE CONDUCTOR ASSN STD SINGLE MATERIAL RESPONSE AST- B298 |
| PMLC | PRECIOUS MATERIAL AND LOCATION | SILVER SURFACE SINGLE CONDUCTOR AND SILVER SURFACE SHIELD BRAID |
| PRMT | PRECIOUS MATERIAL | SILVER |
| SFTT | SURFACE TREATMENT | CORE CONDUCTOR SINGLE CONDUCTOR SILVER |
| STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR SINGLE CONDUCTOR ASSN STD SINGLE TREATMENT RESPONSE AST- B298 |
| ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY STRAND QUANTITY PER CONDUCTOR AND STRAND AWG SIZE PER CONDUCTOR AND BY THE REPLY TO PAC FEAT |