NSN 5915-01-336-3011 · NIIN 013363011 · FSC 5915
NO DASHES 5915013363011
In Stock
FILTER,LOW PASS
Filters and Networks
Application: SIMULATOR,AIRBORNE JAMMER AN/ALT-40(V)
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.990 |
| ADAR | BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.250 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 71.0 |
| AGAV | END ITEM IDENTIFICATION | SIMULATOR,AIRBORNE JAMMER AN/ALT-40(V) |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED GIGAHERTZ BLANK 12.5 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 28687 |
| AHBP | INPUT TERMINAL IDENTIFICATION | SMA-CONNECTOR PLUG |
| AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 28687 |
| AHBT | OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
| AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.5 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED TERMINAL 2 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 0.6 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, PLUG INPUT 1 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.00 AND GIGAHERTZ BLANK 12.50 AND GIGAHERTZ BLANK 15.30 AND GIGAHERTZ BLANK 18.30 |
| CQRG | BODY MATERIAL | METAL |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.00 AND GIGAHERTZ BLANK 12.50 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED MINIMUM BLANK 0.6 AND MAXIMUM BLANK 60.0 |
| CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.0 AND GIGAHERTZ BLANK 12.5 |
| STYL | STYLE DESIGNATOR |