Technical characteristics from the federal item record
MRCRequirementValue
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES AC 3.0
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AAJETHREAD PITCH DIAMETERSINCHES 0.3503 TO 0.3537
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MAXIMUM 0.380
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 6
CMLPTHREAD QUANTITY PER INCH32
CPRWACTUATOR FUNCTIONTRIP-RESET
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.150 AND MAXIMUM AT 200 PCT 0.600
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSALT SPRAY PROOF AND SHOCKPROOF AND VIBRATIONPROOF
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.438
FREQFREQUENCY IN HERTZ400.0
ADAQBODY LENGTHINCHES MAXIMUM 1.500
ADATBODY WIDTHINCHES MAXIMUM 1.875
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 3.0
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
MATTMATERIALCASE PLASTIC
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION MILLIAMPERES AC 0.05
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CQJXNOMINAL THREAD SIZEINCHES 0.375
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO