Home / MS parts / NSN 5925-00-121-9847
NSN 5925-00-121-9847  ·  NIIN 001219847  ·  FSC 5925
NO DASHES 5925001219847
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
FREQFREQUENCY IN HERTZ400.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809
CQJXNOMINAL THREAD SIZEINCHES 0.438
CQSMSWITCH LOCATION AND POSITION DESIGNATIONEXTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND EXPLOSION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
CRTKSWITCH TERMINAL TYPETAB, SOLDER LUG
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 115.0 AND DC 28.0
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION MILLIAMPERES AC 500.0 AND MILLIAMPERES DC 500.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 100.0 AND DC 100.0
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
ADATBODY WIDTHINCHES MAXIMUM 0.580
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.593
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, SINGLE THROW, NORMALLY CLOSED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.420
AKPXPOLE QUANTITY1
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYCONTROL 1
CPRQRESET METHODMANUAL
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES NOMINAL 0.359
ADAQBODY LENGTHINCHES MAXIMUM 0.780
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S26574
TTQYTERMINAL TYPE AND QUANTITYSCREW 2
THSDTHREAD SERIES DESIGNATORUN