Home / MS parts / NSN 5915-01-107-0908
NSN 5915-01-107-0908  ·  NIIN 011070908  ·  FSC 5915
NO DASHES 5915011070908
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

27 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 1.660
ABKWOVERALL HEIGHTINCHES NOMINAL 0.500
ADAQBODY LENGTHINCHES NOMINAL 0.910
ADATBODY WIDTHINCHES NOMINAL 1.690
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 0.663
AECRVIBRATION RESISTANCE RANGE IN HERTZ128.0 TO 2000.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.435
AFGAOPERATING TEMP RANGECELSIUS -54.0 TO 85.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 1.0
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK
AHBZVOLTAGE STANDING WAVE RATIO PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED BLANK 1.6
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 2
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 1.0
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 250.00 AND HERTZ BLANK 900.00 AND KILOHERTZ BLANK 1.10 AND KILOHERTZ BLANK 1.25
CQJXNOMINAL THREAD SIZEINCHES 0.112
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 900.00 AND KILOHERTZ BLANK 1.10
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 20.0 AND MINIMUM BLANK 12.0
CRBNVOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 900.0 AND KILOHERTZ BLANK 1.1
PMLCPRECIOUS MATERIAL AND LOCATIONGOLD CONNECTOR BODY AND HARDWARE
PRMTPRECIOUS MATERIALGOLD
STYLSTYLE DESIGNATOR