Home / MS parts / Electrical & Electronic Components / NSN 5950-00-984-5365
NSN 5950-00-984-5365  ·  NIIN 009845365  ·  FSC 5950
NO DASHES 5950009845365
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

25 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AKPVMOUNTING FACILITY QUANTITY4
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 745.0
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 220.0
ADAQBODY LENGTHINCHES NOMINAL 2.750
ADATBODY WIDTHINCHES NOMINAL 2.375
ADAUBODY HEIGHTINCHES NOMINAL 3.812
CMLPTHREAD QUANTITY PER INCH32
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.30
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 110.00
AXGYMOUNTING METHODSINGLE GROUP THREADED STUD(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 4
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 60.0
AARGRELIABILITY INDICATORNOT ESTABLISHED
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 260.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 51.50
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYSOLDER STUD 14
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 50.00
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750