Home / MS parts / NSN 5925-01-537-6131
NSN 5925-01-537-6131  ·  NIIN 015376131  ·  FSC 5925
NO DASHES 5925015376131
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

33 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
FREQFREQUENCY IN HERTZ400.0
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 6
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0 AND DC 50.0
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
CRTKSWITCH TERMINAL TYPETAB, SOLDER LUG
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.055 AND MAXIMUM AT 200 PCT 2.000
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MAXIMUM 0.380
ADAQBODY LENGTHINCHES MAXIMUM 1.937
ADATBODY WIDTHINCHES MAXIMUM 1.562
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.375
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0 AND DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 500.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 6.0 AND AMPERES DC 6.0