NSN 6665-01-112-4050 · NIIN 011124050 · FSC 6665
NO DASHES 6665011124050
In Stock
METER,MICROWAVE SURVEY
Hazard-Detecting Instruments and Apparatus
Technical characteristics
4 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | METER MICROWAVE SURVEY PORTABLE BATTERY-POWERED |
| ECWT | EXTERIOR CONTAINER WEIGHT | POUNDS 3.00 |
| FEAT | SPECIAL FEATURES | BATTERY 7.2V RECHARGEABLE, LESS THAN 20 HOURS PER CHARGE; DISPLAYS FIELDS IN ANY UNIT: MW/CM2, W/M2, V/M, A/M, V2/M2, A2/M2, PJ/CM3, AND PERCENT OF INTERNATIONAL STANDARDS; MOST ACCURATE NON-IONIZING RADIATION SURVEY SYSTEM; PROVIDES THE BROADEST FREQUENCY COVERAGE OF BOTH ELECTRIC AND MAGNETIC FIELDS |
| TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | 11.3 IN. BY 3.4 IN. BY 2.2 IN.; MICROPROCESSOR-BASED DESIGN; SMALL; LIGHTWEIGHT; ERGONOMIC DESIGN; 4 LINE X 20 CHARACTER DOT MATRIX LIQUID CRYSTAL DISPLAY W/BACK LIGHT; 22 KEY MEMBRANE KEYPAD; PROBE CABLE INPUT; FIBER OPTIC LINK INPUT; RS232 INTERFACE; PROBE RF TEST SOURCES (DUAL FREQUENCY); RECORDER OUTPUT; ONE-TOUCH AUTO ZERO; TIME AND SPATIAL AVERAGING WITH DATA STORAGE; CALCULATE PERCENT OF STANDARD; SOPHISTICATED DATA LOGGING; MULTILEVEL ADJUSTABLE AUDIO OUTPUT PROPORTIONAL TO FIELD STRENGTH; PROBE OVERLOAD WARNING; OPERATING TEMP: -10 DEG C TO +50 DEG C; NON-OPERATING: -20 DEG C TO +70 DEG C |