NSN 5945-00-201-5182 · NIIN 002015182 · FSC 5945
NO DASHES 5945002015182
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 120.0 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES AC 5.5 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 675.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1 |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 60.0 |
| APCN | COIL QUANTITY | 1 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.245 |
| ADAV | OVERALL DIAMETER | INCHES NOMINAL 2.020 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 120.0 AND DC 24.0 |
| AKDX | WINDING QUANTITY | 1 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 20.0 AND AMPERES DC 20.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 8 |
Supersedes
This item replaces cancelled NIINs 002836340 · 003312806. An older drawing citing one of those numbers resolves here.