NSN 6105-01-365-9212 · NIIN 013659212 · FSC 6105
NO DASHES 6105013659212
In Stock
MOTOR,ALTERNATING CURRENT
Motors, Electrical
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJT | OVERALL HEIGHT | INCHES 9.880 |
| AAJU | OVERALL LENGTH | INCHES 15.620 |
| AAJV | OVERALL WIDTH | INCHES 9.590 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ANPZ | ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| AXCP | WINDING TYPE | SHUNT WOUND |
| AXGY | MOUNTING METHOD | FLANGE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 8 |
| BFMF | COOLING METHOD | FAN COOLED |
| BKPB | CURRENT RATING METHOD | LOAD |
| BKPH | TORQUE RATING AND TYPE | FOOT-POUNDS RUNNING 12.1 |
| BKPQ | INCLOSURE SPECIFICATION | NEMA |
| BYDT | BEARING TYPE | ANNULAR BALL |
| CNMM | FRAME SIZE DESIGNATION | 184T |
| CNXS | POWER RATING | OUTPUT HORSEPOWER 4.000 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWCS | LENGTH OF SHAFT FROM HOUSING | FIRST END INCHES 3.000 |
| CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | FIRST END INCHES 4.300 |
| CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 3.750 |
| CWDY | TEMP RATING | AMBIENT CELSIUS 50.0 |
| CWFX | ROTOR SPEED RATING IN RPM | SINGLE FULL LOAD 1700.0 |
| CWGL | CURRENT RATING IN AMPS | INPUT SINGLE 6.000 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO LINE SINGLE 460.0 |
| FAAZ | PHASE | INPUT THREE |
| FEAT | SPECIAL FEATURES | MOTOR IS WATERTIGHT,TOTALLY ENCLOSED AIR OVER,SERVICE FACTOR OF 1.0,REMOVABLE LIFT LUG. |
| FREQ | FREQUENCY IN HERTZ | 60.0 |