NSN 4120-01-449-0459 · NIIN 014490459 · FSC 4120
NO DASHES 4120014490459
In Stock
AIR CONDITIONER
Air Conditioning Equipment
Application: PORTABLE SHELTERS OR VANS
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAXX | MOUNTING TYPE | FLOOR |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 52.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 31.750 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 42.000 |
| ACDC | CURRENT TYPE | AC |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| AFPS | ENERGY EFFICIENCY RATIO | 4.8 |
| AFSS | DESIGN CURRENT RATING IN AMPS | NOMINAL 60.0 |
| AGAV | END ITEM IDENTIFICATION | PORTABLE SHELTERS OR VANS |
| ALCD | USAGE DESIGN | COMPRESSOR,HEATER |
| AMSE | VOLTAGE RATING | VOLTS MINIMUM 208.0 AND VOLTS MAXIMUM 220.0 |
| ARNA | COOLANT TYPE | HFC-134A |
| AWLX | ELECTRIC MOTOR QUANTITY | 1 |
| AWXK | REFRIGERANT CAPACITY | POUNDS 14.000 |
| AWZJ | POWER SOURCE | ELECTRIC MOTOR |
| AZQK | WEIGHT | POUNDS NOMINAL 800.000 |
| AZSD | COMPRESSOR UNIT TYPE | HERMETICALLY SEALED |
| AZSF | NOMINAL COOLING CAPACITY | CUBIC FEET PER MINUTE 2200.0 |
| CPZH | MAXIMUM AIR CAPACITY IN CUBIC FEET PER MINUTE | 2200.000 |
| CTMG | KILOWATT RATING | 14.0 |
| CYJE | COOLING CAPACITY IN BTU PER HOUR | NOMINAL 65000.0 |
| CYKM | HEATING CAPACITY IN BTU PER HOUR | NOMINAL 48000.0 |
| FAAZ | PHASE | THREE |
| FEAT | SPECIAL FEATURES | CONDITIONER IS NBC CAPABLE,THE FEDCU2 USES TWO COMPRESSOR CRANKCASE HEATERS AND HAS COMPRESSOR WARM UP INDICATOR LIGHTS TO INDICATE HEATER OPERATION IS USED TO PROVIDE COOLED AND DEHUMIDIFIED AIR OR HEATED AIR TO PORTABLE SHELTERS OR VANS IAW ELECTRONIC AND PERSONNEL REQUIREMENTS |