NSN 5945-00-829-2869 · NIIN 008292869 · FSC 5945
NO DASHES 5945008292869
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
34 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.687 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 50.0 AND AMPERES DC 50.0 |
| CBME | CUBIC MEASURE | CUBIC INCHES 36.294 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.865 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.941 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 3.305 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.218 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD 96906--S27222 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.05 |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION 1 AND POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION 1 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.025 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 50.0 AND AMPERES DC 50.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 4 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| APCN | COIL QUANTITY | 1 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS THREADED STUD 12 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 50.0 AND AMPERES DC 50.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 1.0 AND AMPERES DC 1.0 |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 3.734 |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 400.0 |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION 3 |