Home / MS parts / NSN 5925-00-511-3082
NSN 5925-00-511-3082  ·  NIIN 005113082  ·  FSC 5925
NO DASHES 5925005113082
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

32 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 5.0 AND AMPERES DC 5.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 200.0 AND DC 28.0
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 3
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYSCREW 6
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 25.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 3
AKPXPOLE QUANTITY3
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES NOMINAL 0.250
ADAQBODY LENGTHINCHES NOMINAL 1.218
ADATBODY WIDTHINCHES NOMINAL 2.437
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 6000.0 AND DC 35000.0
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.469
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 400 PCT 2.000 AND MAXIMUM AT 400 PCT 10.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 1.703
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.875
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.701

Supersedes

This item replaces cancelled NIIN 009666433. An older drawing citing one of those numbers resolves here.