Home / MS parts / Electrical & Electronic Components / NSN 5950-01-099-4734
NSN 5950-01-099-4734  ·  NIIN 010994734  ·  FSC 5950
NO DASHES 5950010994734
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

22 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.000
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.000
ABMKOVERALL WIDTHINCHES MAXIMUM 2.680
ABTBMOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.213
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 45.0 AND HERTZ MAXIMUM 440.0
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
ACZDTRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
ACZXWINDING SHIELDING METHODSINGLE COMPONENT PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL
ADAQBODY LENGTHINCHES MAXIMUM 3.500
ADATBODY WIDTHINCHES MAXIMUM 1.800
ADAUBODY HEIGHTINCHES MAXIMUM 2.750
AEHZMAXIMUM OPERATING TEMPCELSIUS 65.0
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP FLANGE AND UNTHREADED HOLE(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 50.0
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC MAXIMUM 30.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 4.40
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 440.00
TTQYTERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 8