TRAINER,DEFIBRILLATOR

Training Aids

Application: TEMPUS ALS DEFIBRILLATOR

Technical characteristics

12 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AWZJPOWER SOURCEBATTERY
BBDBTRAINING PHASE20 TOTAL: 14 X CORE ACLS WAVEFORMS - VENTRICULAR FIBRILLATION; VENTRICULAR TACHYCARDIA - FAST WITH WIDE QRS; VENTRICULAR TACHYCARDIA - SLOW WITH WIDE QRS; TORSADES DE POINTES; ATRIAL FIBRILLATION WITH RAPID VARYING VENTRICULAR RESPONSE; AFLUTTER WITH 2:1 AV BLOCK; PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIA; SINUS TACHYCARDIA WITH ANTERIOR ST DEPRESSION; NORMAL SINUS RHYTHM; ASYSTOLE; 1ST DEGREE AV BLOCK WITH RBBB; 2ND DEGREE TYPE II AV BLOCK (4:3); 2ND DEGREE TYPE II AV BLOCK WITH LBBB AND PVCS (4:3); 3RD DEGREE AV BLOCK. 6 X ST SEGMENT AND T WAVE ABNORMALITIES - SINUS RHYTHM WITH ANTERIOR Q WAVES; SINUS RHYTHM WITH ANTERIOR Q WAVES AND PVCS; SINUS RHYTHM WITH ANTEROSEPTAL ST ELEVATION; 2ND DEGREE TYPE I AV BLOCK WITH LATERAL ST ELEVATION; SINUS BRADYCARDIA WITH INFERIOR ST ELEVATION; SINUS BRADYCARDIA WITH INFERIOR ST ELEVATION AND Q WAVES.
BBDXEQUIPMENT NAMECS1201 ECG SIMULATOR
CFTLREPRESENTATION TYPESIMULATION
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYCS1201 ECG SIMULATOR
FEATSPECIAL FEATURESDEFIBRILLATOR AND PACER TRAINING. ECG CONNECTIONS: V1 - V6; RA, LA, LL, RL; PADS. DEFIBRILLATOR DISCHARGE: THE SIMULATOR DETECTS DEFIB DISCHARGES OF 50J OR GREATER. THE DEFIB DSCHG INDICATOR ILLUMINATES WHEN DEFIB DETECTION OCCURS. CONVERT: CONVERT, THE WAITING RHYTHM THAT YOU PRE-SELECT AUTOMATICALLY BECOMES THE RUNNING RHYTHM WHEN A DEFIBRILLATOR DISCHARGE IS DETECTED. PACING CAPTURE CURRENT/FOUR PACING CAPTURE CURRENT LEVELS: 70, 80, 90 AND 100 MA. PACED BEATS: WHEN A PACER PULSE IS DETECTED, PACED BEATS ARE DISPLAYED ON YOUR ECG MONITOR AND THE PACER PULSE INDICATOR BLINKS OFF MOMENTARILY. FOUR AA ALKALINE BATTERIES. LOW BATTERY INDICATOR. BATTERY SAVER FEATURE POWERS-OFF THE SIMULATOR AUTOMATICALLY WHEN NOT IN USE. BATTERY LIFE IS APPROXIMATELY 15 HOURS. ADDITONAL ORDER NUMBERS: ZOLL: 9851-000; PHYSIO-CONTROL: 9851-001; RDT/TEMPUS LS: 9851-018; WELCH ALLYN: 9851-017. MRL: 9851-017; MARQUETTE: 9851-002.
AGAVEND ITEM IDENTIFICATIONTEMPUS ALS DEFIBRILLATOR
AXEBIDENTIFYING NUMBERCS1201
AZZFBATTERY USAGEREQUIRED
AMQYINSTALLATION DESIGNMOBILE
AMSACONTROLLING AGENCY5BV42/KD792
ANLJBATTERY VOLTAGE RATING IN VOLTS1.5