NSN 5915-00-004-7604 · NIIN 000047604 · FSC 5915
NO DASHES 5915000047604
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 0.547 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 0.525 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.410 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.360 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -50.0 TO 70.0 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 22.8 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED TERMINAL 3 |
| CBBL | FEATURES PROVIDED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 3.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 2 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 22.344 AND MEGAHERTZ BLANK 22.572 AND MEGAHERTZ BLANK 23.028 AND MEGAHERTZ BLANK 23.256 |
| CQRG | BODY MATERIAL | PLASTIC |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 22.572 AND MEGAHERTZ BLANK 23.028 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED MINIMUM BLANK 3.0 AND MAXIMUM BLANK 60.0 |
| CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 22.572 AND MEGAHERTZ BLANK 23.028 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| FEAT | SPECIAL FEATURES | AS DIFFERENTIATED BY CIRCUIT TEST FOR Q-FACTOR; UNPACKAGED UNIT WEIGHT: OZ2.000 |
| STYL | STYLE DESIGNATOR |