NSN 5925-00-930-2265 · NIIN 009302265 · FSC 5925
NO DASHES 5925009302265
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
42 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MINIMUM 10.970 AND INCHES MAXIMUM 11.030 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| PMLC | PRECIOUS MATERIAL AND LOCATION | SILVER CONTACTS |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES MINIMUM 0.340 AND INCHES MAXIMUM 0.400 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | INCHES MINIMUM 0.350 AND INCHES MAXIMUM 0.410 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 14.220 AND INCHES MAXIMUM 14.280 |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 600.0 AND DC 125.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES MINIMUM 2.720 AND INCHES MAXIMUM 2.780 |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | AC 6.0 AND DC 0.5 |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS THERMAL-MAGNETIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS INSTANTANEOUS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 25000.0 AND DC 65000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | CONTROL 1 |
| AEGJ | SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, DOUBLE THROW |
| CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
| AAQL | BODY STYLE | |
| ADAQ | BODY LENGTH | INCHES MINIMUM 15.470 AND INCHES MAXIMUM 15.530 |
| ADAT | BODY WIDTH | INCHES MINIMUM 8.220 AND INCHES MAXIMUM 8.280 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 11.590 AND INCHES MAXIMUM 11.650 |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES MINIMUM 2.720 AND INCHES MAXIMUM 2.780 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 40.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 600.0 AND DC 125.0 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND WEATHERPROOF |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 700.0 AND AMPERES DC 700.0 |
| PRMT | PRECIOUS MATERIAL | SILVER |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 6 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 4 |
| AKPX | POLE QUANTITY | 3 |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
| CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | ALL LOCATIONS AC 2100.0 TO 7000.0 AND DC 2100.0 TO 7000.0 |