NSN 4140-00-938-1414 · NIIN 009381414 · FSC 4140
NO DASHES 4140009381414
In Stock
FAN,VANEAXIAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADNK | FLOW DIRECTION | INWARD |
| AGBD | ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 50.0 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 26.0 OR DC 28.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 3 |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 1.990 |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| MATT | MATERIAL | OVERALL ALUMINUM ALLOY |
| SFTT | SURFACE TREATMENT | OVERALL ENAMEL |
| STYL | STYLE DESIGNATOR | |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABRY | LENGTH | INCHES NOMINAL 1.470 |
| AKCV | DRIVE TYPE | DIRECT |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS -55.0 AND CELSIUS 85.0 |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 20500.0 |
| CSYL | PRIME MOVER POWER RATING | WATTS 42.0 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AAYD | STAGE QUANTITY | 1 |