NSN 4140-00-792-0873 · NIIN 007920873 · FSC 4140
NO DASHES 4140007920873
In Stock
FAN,VANEAXIAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAYD | STAGE QUANTITY | 1 |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABRY | LENGTH | INCHES NOMINAL 1.600 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | OVERALL MIL SPEC SINGLE TREATMENT RESPONSE -IL-E-5557,TY 4 |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | CLAMP 1 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| CBBL | FEATURES PROVIDED | SAFETY IMPELLER GUARD |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 21.0 |
| STYL | STYLE DESIGNATOR | |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| MATT | MATERIAL | OVERALL ALUMINUM ALLOY |
| SFTT | SURFACE TREATMENT | OVERALL ENAMEL |
| CSYL | PRIME MOVER POWER RATING | WATTS 16.0 |
| ADNK | FLOW DIRECTION | INWARD |
| ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND SHOCK PROOF |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS -54.0 AND CELSIUS 125.0 |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 22000.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 1.562 |
| FAAZ | PHASE | SINGLE |