NSN 5930-01-226-9978 · NIIN 012269978 · FSC 5930
NO DASHES 5930012269978
In Stock
SWITCH,FLOW
Switches
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2A |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 2.812 AND INCHES MAXIMUM 4.906 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.531 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.250 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.000 |
| AWTN | OPERATING TEMP RATING | CELSIUS MAXIMUM 55.0 |
| AXGY | MOUNTING METHOD | THREADED STUD(S) |
| CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | SINGLE THREADED STUD INCHES 0.190 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 1.0 |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT MINIMUM FEET PER MINUTE 720.00 AND ACTUATION POINT MAXIMUM FEET PER MINUTE 4000.00 AND DIFFERENTIAL POINT MINIMUM FEET PER MINUTE 105.00 AND DIFFERENTIAL POINT MAXIMUM FEET PER MINUTE 320.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE DC AT SEA LEVEL 28.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 250.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| STYL | STYLE DESIGNATOR | |
| THSD | THREAD SERIES DESIGNATOR | SINGLE THREADED STUD UNF |