NSN 5996-01-706-3724 · NIIN 017063724 · FSC 5996
NO DASHES 5996017063724
In Stock
AMPLIFIER,VIDEO
Amplifiers
Application: F16 AIRCRAFT
Technical characteristics
8 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| SUPP | SUPPLEMENTARY FEATURES | FREQUENCY RANGE: FROM 150 TO 200 MEGAHERTZ AND FROM 900 TO 1050 MEGAHERTZ;POWER SUPPLY CHARACTERISTICS: +15 VOLTAGE, + OR - 5% VOLTAGE TOLERANCE, MAXIMUM CURRENT: 300 MILLIAMPERES MAXIMUM, MAXIMUM FORWARD VOLTAGE: +18VDC, MAXIMUM REVERSE VOLTAGE: -25VDC; -15 NOMINAL VOLTAGE: + OR - 5% VOLTAGE TOLERANCE, MAXIMUM CURRENT: MILLIAMPERES, MAXIMUM FORWARD VOLTAGE: -18VDC, MAXIMUM REVERSE VOLTAGE: +25VDC |
| FTLD | FUNCTIONAL DESCRIPTION | RELIABILITY: UNIT SHALL EXHIBIT A MAXIMUM FAILURE RATE OF 20 FAILURES PER 1 MILLION HOURS |
| FEAT | SPECIAL FEATURES | TANGENTIAL SENSITIVITY: -75DBM MINIMUM; LOGGING RANGE: -70DBM TO -10DBM MINIMUM |
| AFGA | OPERATING TEMP RANGE | CELSIUS -40.0 TO 95.0 |
| AGAV | END ITEM IDENTIFICATION | F16 AIRCRAFT |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | AMPLIFIER, DETECTOR LOG VIDEO |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| SPCL | SPECIAL TEST FEATURES | MAXIMUM INPUT POWER: +26DBM; UNIT SHALL PROVIDE FULL PERFORMANCE WITH A LOAD IMPEDANCE OF 100OHMS FROM 1 TO 15 FEET OF RG180B/U CABLE AND UP TO 15 PF LUMPED CAPACITANCE IN PARALLEL WITH 15 PF CAPACITANCE OF THE MEASUREMENT SLOPE; UNIT SHALL MAINTAIN STABLE OPERATION WITH A LOAD IMPEDANCE OF 100 OHMS WITH + OR - 5% |