Technical characteristics from the federal item record
MRCRequirementValue
MATTMATERIALCASE PLASTIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
AJECBOSS HEIGHTINCHES NOMINAL 0.125
AKPXPOLE QUANTITY3
FREQFREQUENCY IN HERTZ60.0
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCKPROOF AND VIBRATIONPROOF
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 50.0 AND AMPERES DC 50.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 125.0 AND DC 125.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 5000.0 AND DC 5000.0
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 4.125
ADATBODY WIDTHINCHES NOMINAL 3.344
ADAUBODY HEIGHTINCHES NOMINAL 3.375
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-17588
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYQUICK DISCONNECT, MALE 6
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 2.625
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.125
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 0.500
CPRQRESET METHODMANUAL
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED STUD(S) 2
CMLPTHREAD QUANTITY PER INCH24
CQJXNOMINAL THREAD SIZEINCHES 0.216
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 125 PCT 10.000 AND MAXIMUM AT 125 PCT 100.000
CPRPULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS NOMINAL 3600.000
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.937
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPRWACTUATOR FUNCTIONTRIP-RESET