Home / MS parts / NSN 5925-00-417-2784
NSN 5925-00-417-2784  ·  NIIN 004172784  ·  FSC 5925
NO DASHES 5925004172784
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRQRESET METHODMANUAL
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
AAJETHREAD PITCH DIAMETERSINCHES 0.1177 TO 0.1214
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MINIMUM 2.480 AND INCHES MAXIMUM 2.500
ADATBODY WIDTHINCHES MAXIMUM 0.750
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 5.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 240.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.940
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.050 AND INCHES MAXIMUM 2.070
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHTINCHES NOMINAL 0.150
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.475
CPRWACTUATOR FUNCTIONTRIP-RESET
CMLPTHREAD QUANTITY PER INCH32
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 2
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.100 AND MAXIMUM AT 200 PCT 20.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55629
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
BBRJSPECIAL HANDLING FEATUREMAGNETIC
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-55629 TO 1

Supersedes

This item replaces cancelled NIIN 009469422. An older drawing citing one of those numbers resolves here.