NSN 5925-00-615-8376 · NIIN 006158376 · FSC 5925
NO DASHES 5925006158376
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
32 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES MINIMUM 1.448 AND INCHES MAXIMUM 1.510 |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 0.870 AND INCHES MAXIMUM 0.880 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MINIMUM 1.524 AND INCHES MAXIMUM 1.586 |
| AKPX | POLE QUANTITY | 1 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| AAJE | THREAD PITCH DIAMETERS | INCHES 0.3503 TO 0.3537 |
| AAQL | BODY STYLE | |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| ADAT | BODY WIDTH | INCHES MINIMUM 0.567 AND INCHES MAXIMUM 0.629 |
| ABXD | BUSHING LENGTH | INCHES MINIMUM 0.360 AND INCHES MAXIMUM 0.380 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 2 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.375 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION NOMINAL AT 300 PCT 0.140 AND NOMINAL AT 400 PCT 0.080 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 250.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 240.0 AND DC 32.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1000.0 AND DC 1000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 |
Supersedes
This item replaces cancelled NIIN 007271442. An older drawing citing one of those numbers resolves here.