Home / MS parts / NSN 5925-01-092-6395
NSN 5925-01-092-6395  ·  NIIN 010926395  ·  FSC 5925
NO DASHES 5925010926395
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

49 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAJETHREAD PITCH DIAMETERSINCHES 0.1177 TO 0.1214
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MINIMUM 2.480 AND INCHES MAXIMUM 2.500
ADATBODY WIDTHINCHES MAXIMUM 4.515
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.925 AND INCHES MAXIMUM 1.955
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.050 AND INCHES MAXIMUM 2.070
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHTINCHES MINIMUM 0.135 AND INCHES MAXIMUM 0.165
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.625
AKPXPOLE QUANTITY6
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 12
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION AMPERES AC 15.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES AC 15.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIFTH LOCATION AMPERES AC 7.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFOURTH LOCATION AMPERES AC 7.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESIXTH LOCATION AMPERES AC 7.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 15.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 6
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE FOUR AND INTERNAL AT POLE FIVE AND INTERNAL AT POLE SIX
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 22.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF
CRTKSWITCH TERMINAL TYPEPIN
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 10.0
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 22.200
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 12