Home / MS parts / NSN 5925-01-074-3043
NSN 5925-01-074-3043  ·  NIIN 010743043  ·  FSC 5925
NO DASHES 5925010743043
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

52 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAJETHREAD PITCH DIAMETERSINCHES 0.1177 TO 0.1214
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 2.490
ADATBODY WIDTHINCHES MAXIMUM 3.015
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.940
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.060
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
AJECBOSS HEIGHTINCHES NOMINAL 0.150
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.491
AKPXPOLE QUANTITY4
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 8
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 25.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION AMPERES AC 25.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES AC 25.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFOURTH LOCATION DC 24.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSECOND LOCATION AC 250.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSTHIRD LOCATION AC 250.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFIRST LOCATION AC 250.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSFIRST LOCATION AC 5000.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSTHIRD LOCATION AC 5000.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSECOND LOCATION AC 5000.0
CPRHCIRCUIT PROTECTION TYPETHIRD LOCATION OVERCURRENT
CPRHCIRCUIT PROTECTION TYPEFOURTH LOCATION OVERVOLTAGE
CPRHCIRCUIT PROTECTION TYPEFIRST LOCATION OVERCURRENT
CPRHCIRCUIT PROTECTION TYPESECOND LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICFOURTH LOCATION INSTANTANEOUS
CPRLTRIP RELEASE CHARACTERISTICTHIRD LOCATION TIME DELAY
CPRLTRIP RELEASE CHARACTERISTICFIRST LOCATION TIME DELAY
CPRLTRIP RELEASE CHARACTERISTICSECOND LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 4
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, AND FOUR LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONFIRST LOCATION SHUNT TRIP
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSECOND LOCATION SHUNT TRIP
CPSMINTERNAL TRIP RELEASE CONFIGURATIONFOURTH LOCATION SERIES TRIP
CPSMINTERNAL TRIP RELEASE CONFIGURATIONTHIRD LOCATION SHUNT TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND MOISTURE RESISTANT
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 11