NSN 5915-00-556-2189 · NIIN 005562189 · FSC 5915
NO DASHES 5915005562189
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.500 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.750 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.125 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.750 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION WIRE HOOK OUTPUT 2 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.196 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.500 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| CQRG | BODY MATERIAL | METAL |
| STYL | STYLE DESIGNATOR | |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 4.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 4.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 4.000 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 4.000 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0 |