Home / MS parts / NSN 5925-00-960-2835
NSN 5925-00-960-2835  ·  NIIN 009602835  ·  FSC 5925
NO DASHES 5925009602835
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 6
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT130.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND HERMETICALLY SEALED AND MOISTURE RESISTANT
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 4.500
FREQFREQUENCY IN HERTZ400.0
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION AMPERES AC 12.0
PRMTPRECIOUS MATERIALSILVER
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES NOMINAL 0.375
ADAQBODY LENGTHINCHES NOMINAL 1.495
ADATBODY WIDTHINCHES NOMINAL 1.872
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 1.678
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 4.4
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES AC 4.4
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER CONTACT SURFACES
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.100 AND MAXIMUM AT 200 PCT 0.700
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CPRQRESET METHODMANUAL
THSDTHREAD SERIES DESIGNATORUNEF
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET