NSN 5950-01-190-7523 · NIIN 011907523 · FSC 5950
NO DASHES 5950011907523
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | ALL MOUNTING FACILITIES SINGLE CENTER GROUP INCHES NOMINAL 2.500 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | ALL MOUNTING FACILITIES SINGLE CENTER GROUP INCHES NOMINAL 2.500 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MINIMUM 3.180 AND INCHES MAXIMUM 3.260 |
| ADAT | BODY WIDTH | INCHES MINIMUM 3.180 AND INCHES MAXIMUM 3.260 |
| ADAU | BODY HEIGHT | INCHES MINIMUM 5.040 AND INCHES MAXIMUM 5.120 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CQJX | NOMINAL THREAD SIZE | ALL GROUPINGS INCHES 0.164 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC MAXIMUM 370.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE PRIMARY VOLTS-AMPERES 4.2 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| THSD | THREAD SERIES DESIGNATOR | ALL GROUPINGS UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 2 AND PIN 2 |