NSN 5945-00-241-4652 · NIIN 002414652 · FSC 5945
NO DASHES 5945002414652
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.120 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.688 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.719 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.120 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.430 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.161 |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 300.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | INERT GAS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2 |
| AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 4A |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY DIAGONAL |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 4 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 80.0 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 26.5 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 15.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 10 |