NSN 6145-00-258-6977 · NIIN 002586977 · FSC 6145
NO DASHES 6145002586977
In Stock
CABLE,SPECIAL PURPOSE,ELECTRICAL
Wire and Cable, Electrical
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| ABJH | TEMP RATING | CELSIUS -55.0 AND CELSIUS 105.0 |
| ADVL | CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.180 |
| AMQN | CONDUCTOR QUANTITY | 3 |
| BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 |
| CXCW | CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| CXDC | ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 22 |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 |
| CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | TRIPLES 1 |
| CXFK | VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0 |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR RED |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR BLACK |
| HUES | COLOR | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR WHITE |
| HUES | COLOR | FOURTH POSITION JACKET CABLE GRAY/GREY |
| MATT | MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| MATT | MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC) |
| MATT | MATERIAL | FOURTH POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC) |
| MATT | MATERIAL | SECOND POSITION JACKET ALL CONDUCTORS PLASTIC POLYAMIDE NYLON |
| MATT | MATERIAL | THIRD POSITION SHIELD BRAID METALLIC CABLE COPPER |
| MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B33 |
| SFTT | SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| SFTT | SURFACE TREATMENT | THIRD POSITION SHIELD BRAID METALLIC CABLE TIN |
| STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B33 |