NSN 5950-00-465-8290 · NIIN 004658290 · FSC 5950
NO DASHES 5950004658290
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
32 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 34.20 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.380 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY DC VOLTS NOMINAL 11.40 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 34.20 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 41.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 3.5 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 16.4 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 3.5 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.748 AND INCHES MAXIMUM 1.752 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.310 AND INCHES MAXIMUM 1.314 |
| FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND FIVE SECONDARY WINDINGS |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 37695-328720 |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 19 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 2.750 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.875 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES DC NOMINAL 1.2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES DC NOMINAL 310.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC NOMINAL 480.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC NOMINAL 310.0 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY DC VOLTS NOMINAL 11.40 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |