NSN 5950-01-029-4169 · NIIN 010294169 · FSC 5950
NO DASHES 5950010294169
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SINGLE PHASE AND THREE PHASE TO SIX PHASE AND THREE PHASE TO THREE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 7.750 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 6.250 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 5.450 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 7 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES DC MAXIMUM 7.5 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES DC MAXIMUM 7.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES DC MAXIMUM 5.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES DC MAXIMUM 7.5 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 135.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 135.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 220.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 189.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY DC VOLTS NOMINAL 18.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 27.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 103.50 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY DC VOLTS NOMINAL 18.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 44.00 |
| FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 7 SECONDARY WINDINGS; SECONDARY VOLTAGES ARE AFTER RECTIFICATION |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 27 |