Home / MS parts / Electrical & Electronic Components / NSN 5950-00-783-3761
NSN 5950-00-783-3761  ·  NIIN 007833761  ·  FSC 5950
NO DASHES 5950007833761
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

27 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABKWOVERALL HEIGHTINCHES NOMINAL 3.750
FEATSPECIAL FEATURES1 PRIMARY; 7 SECONDARIES
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 300.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 2.00 AND AC VOLTS NOMINAL 10.00 AND AC VOLTS NOMINAL 11.00 AND AC VOLTS NOMINAL 16.00 AND AC VOLTS NOMINAL 22.00 AND AC VOLTS NOMINAL 36.00
AXGYMOUNTING METHODSINGLE GROUP THREADED HOLE(S)
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.112
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MINIMUM 30.0 AND MILLIAMPERES AC MAXIMUM 400.0
AARGRELIABILITY INDICATORNOT ESTABLISHED
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 4.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750
ADAQBODY LENGTHINCHES NOMINAL 2.750
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 190.0
ADATBODY WIDTHINCHES NOMINAL 2.375
AEHZMAXIMUM OPERATING TEMPCELSIUS 135.0
AKNAINCLOSURE TYPEHERMETICALLY SEALED WITH OIL
AKPVMOUNTING FACILITY QUANTITY4
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 60.00
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 21.00
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 84.00
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 24